Order securely online or call 800-544-6599
Custom-built, ready-to-edit Tsunami workstationsBrowse our catalog of productsBrowse products by manufacturer
Safe Harbor Computers - Digital Video & 3D Animation Specialists

Safe Harbor Computers - Digital Video & 3D Animation Specialists

Safe Harbor Computers - Digital Video & 3D Animation Specialists
View the contents of your shopping cartCheck the status of an orderCustomer Service and online help

ExpressPCIe UL5D SCSI Host Adapter
The ATTO ExpressPCI UL5D dual-channel Ultra320 host adapter offers the highest SCSI performance for demanding server and professional workstation environments. The ExpressPCI UL5D boasts data-transfer rates of up to 640 MB/second and offers support for PCI Express interconnect – a high-speed (serial) bus interface.

List Price: $599.00
Our Price: $444.99

Add ExpressPCIe UL5D SCSI Host Adapter to Your Cart to Order Securely Online  • or •  Call 800-544-6599 to Order By Phone

ExpressPCIe UL5D SCSI Host Adapter

CATEGORY: Harddrive Controllers PARTNUMBER: ATON5250003
MANUFACTURER: ATTO Technology PLATFORM(S): Apple Mac   &   Windows Win
ON THE WEB: www.attotech.com AVAILABILITY: Usually ships in 2-business days or less.
AVERAGE RATING: Not rated yet!   Write a review! DELIVERY: Packaged - Due to this items unusual size or weight, an extra shipping surcharge may be applied to your order.

ExpressPCIe UL5D SCSI Host Adapter Specifications

This host adapter is an ideal fit for high performance video/audio editing applications as well as Enterprise servers and high-end workstations running high-volume, mission-critical applications such as messaging and databases. Only ATTO ExpressPCI host adapters feature the exclusive Advanced Data Streaming (ADSTM) Technology that allows fast and efficient data movement with reduced CPU utilization.

Features:

  • Ultra320 SCSI performance enables high throughput for servers and high-end workstations
    • Two external channels for aggregate throughput of up to 640 MB/sec.
    • Supports up to 30 SCSI bus IDs
    • Supports Low Voltage Differential (LVD) for cabling up to 12.5 meters per bus
    • Compatible with Single-ended SCSI devices, providing cable distances up to 3 meters
    • Supports all five original requirements of Ultra320 SCSI:
      • Double Transition Clocking
      • Domain Validation
      • Quick Arbitration Select
      • Packetization
      • Cyclical Redundancy Checks
    • Additionally, the UL5D supports Ultra320-specific features such as Free-Running Clock, Read/Write Data Streaming, Flow Control, Training Patterns, Pre-compensation, and Asynchronous Information Protection (AIP)
  • Features Advanced Data Streaming (ADSTM) Technology for controlled acceleration of data transfers
    • Embedded RISC processor for low-overhead operation
    • Bus Mastering capabilities eliminate CPU processing time as a bottleneck
    • Tagged Command Queuing allows multiple commands to be processed in any order
    • Disconnect/Reconnect eliminates wait time between transfers
  • Robust Driver Support
    • Windows® Server 2003, XP/2000
    • Mac® OS X
    • Linux
  • RoHS Compliant
    • Meets the requirements as outlined by the European Union Council of Ministers Directive 2002/95/EC RoHS (Restrictions on the Use of Certain Hazardous Substances in Electrical and Electronic Equipment).

Hardware Specifi cations

  • SCSI Interface:
    • 320 MB/sec. per channel data-transfer rates
    • Two (2) external VHDCI and two (2) internal high-density connectors per channel
    • Low Voltage Differential (LVD) signaling
    • Support for tagged command queuing
    • Backward compatible with Ultra 160, Ultra2, Ultra/WIDE, Fast/WIDE and Narrow SCSI devices
  • Advanced SCSI:
    • Double transition clocking
    • Domain validation
    • Cyclical Redundancy Checking (CRC)
    • Packetization
    • Quick Arbitration Select (QAS)
    • ASPI compliant (for PC users)
    • Bootable from attached disks
    • Support for disconnect/reconnect
    • Support for multiple block sizes
  • General Characteristics:
    • Automatic termination
    • Upper-byte termination for Narrow devices
    • Flash ROM for easy field upgrades
    • Plug and play compatible
    • Includes ATTO ExpressPro-ToolsTM and ATTO Configuration Tool formatting and utility software

Software Specifi cations

  • Driver Support:
    • Windows Server 2003
    • Windows XP
    • Windows® 2000
    • Linux
    • Mac OS X
  • Advanced Data Streaming (ADSTM):
    • Improved PCI system bandwidth use
    • Optimized SCSI-3 algorithms
    • Tagged command queuing
    • Embedded RISC I/O processor

ExpressPCIe UL5D SCSI Host Adapter Frequently-Asked Questions

1. HOW DO I TERMINATE A SCSI BUS?

When a SCSI controller issues a command to one of the devices on the SCSI bus, it does not expect to have that command come back to it. Instead, it expects to hear just the response from the drive it issued a command to. Properly terminating the SCSI bus prevents signal reflection on the cables, essentially absorbing commands when they reach the end of the cable. On an improperly terminated SCSI bus, it is common to have the controller software issue error messages caused by unexpected activities on the bus or to experience complete failure of the bus.

The "golden" rule for SCSI termination is that each end of a SCSI bus must be terminated and no terminator can exist anywhere in between these ends. When you add or remove drives from a SCSI bus, you must comply with this rule.

Each SCSI bus starts with a controller. The controller is terminated. Even if there are no drives attached to it, the controller can still issue commands to search for drives without having those commands reflect. Typically, you will add at least one SCSI drive to the bus. You will do so by connecting a ribbon cable from the controller to the drive. Note that one end of the ribbon must plug into the controller and the other end must plug into the drive. In this case, the drive must also be terminated so that both ends of the bus are terminated according to the rule! If you then add additional drives, you can install the drives anywhere along the cable, providing only the drive on the end is terminated.

The termination rule gets complicated when you try to add both internal and external SCSI drives to a system. Since the rule states that the ends of the SCSI bus must be terminated, obviously the drive connected to the end of the internal cable must be terminated and the drive connected to the end of the external cable must be terminated. Unfortunately, this leaves the controller somewhere in the middle of the bus and it too is terminated. If the controller does not provide automatic termination enable/disable, you must manually disable termination on the SCSI controller.

Note that termination violations might sometimes appear to work. However, it is better to be safe than sorry. Follow the rule!

Terminating a drive usually involves installing or removing a jumper on the drive. Check your drive manual for this jumper setting. If the drive does not provide built-in termination, you can purchase a stand-alone terminator. Terminators are available to plug into most SCSI connectors and come in a whole host of shapes and sizes so get the one designed for your application. Note that most new SCSI drives do not provide a built-in terminator and termination is provide by a separate terminator plugged into the end of the SCSI cable.

May We Take Your Order, Please?

Ordering from Safe Harbor is safe and easy. We offer a variety of ways to order including securely through this website or over the phone, toll-free. Our customers are always pleased with our top-rated customer service, fast shipping and competitive prices.

Safe Harbor appreciates your business! May we please take your order for an ExpressPCIe UL5D SCSI Host Adapter today?

Add ExpressPCIe UL5D SCSI Host Adapter to Your Cart to Order Securely Online  • or •  Call 800-544-6599 to Order By Phone

What Customers are Saying About Safe Harbor
I am truly amazed at the level of service and caring that you put forward in this transaction. I can't thank you enough. I look forward to my next purchase from Safe Harbor. - Pete

Related Resources on Safe Harbor's Website
  NEWS  

ATTO Technology Releases 4th Generation 4-Gigabit Fibre Channel Host AdaptersApril 17

ATTO Technology Demonstrates Innovative Storage Connectivity SolutionsApril 16
ATTO Technology, Inc.


Home   |   Workstations   |   Products   |   Manufacturers   |   Your Cart   |   Order Status   |   Help   |   Contact Us

Safe Harbor ComputersCopyright © 2008 by Safe Harbor Computers. All Rights Reserved. No content from this site may be reproduced or publicly reposted without express written permission.

All product content herein remains the licensed property of their respective distributers and manufacturers.

Questions regarding products or orders can be emailed to: sales@sharbor.com

Order securely online or call:
800-544-6599

For information & support, call:
262-548-8120

Every effort has been made to ensure the accuracy of the information represented on this site. Prices and specifications subject to change without notice. Not responsible for typos.

Explore our site without worry - read our privacy statement. Website questions or comments? webmaster@sharbor.com

Order securely online or call 800-544-6599Safe Harbor Computers - Digital Video & 3D Animation Specialists

Safe Harbor Computers - Digital Video & 3D Animation Specialists

Safe Harbor Computers - Digital Video & 3D Animation Specialists